AZ 16-12ZVRK-M16


| Ordering data | |
|
Product type description
|
AZ 16-12ZVRK-M16 |
| Article number (order number) | 101154221 |
| EAN (European Article Number) | 4,03066E+12 |
| eCl@ss number, version 12.0 | 27-27-26-02 |
| eCl@ss number, version 11.0 | 27-27-26-02 |
| eCl@ss number, version 9.0 | 27-27-26-02 |
| ETIM number, version 7.0 | EC002592 |
| ETIM number, version 6.0 | EC002592 |
| Approvals - Standards | |
|
Certificates
|
TÜV |
| cULus | |
| CCC | |
| EAC | |
| General data | |
|
Standards
|
EN ISO 13849-1 |
| EN ISO 14119 | |
| EN IEC 60947-5-1 | |
| Coding level according to EN ISO 14119 | Low |
| Enclosure material | Plastic, glass-fibre reinforced thermoplastic, self-extinguishing |
| Material of the contacts, electrical | Silver |
| Gross weight | 120 g |
| General data - Features | |
|
Number of auxiliary contacts
|
1 |
| Number of cable glands | 3 |
| Number of safety contacts | 2 |
| Safety classification | |
|
Standards
|
EN ISO 13849-1 |
| Mission time | 20 Year(s) |
| Safety classification - Safety outputs | |
|
B10D Normally-closed contact (NC)
|
2,000,000 Operations |
| B10D Normally open contact (NO) | 1,000,000 Operations |
| Note (B10D Normally open contact (NO)) | at 10% Ie and ohmic load |
| Mechanical data | |
|
Mechanical life, minimum
|
1,000,000 Operations |
| Latching force | 30 N |
| Positive break travel | 8 mm |
| Positive break force per NC contact, minimum | 10 N |
| Positive break force, minimum | 20 N |
| Actuating speed, maximum | 2 m/s |
| Mechanical data - Connection technique | |
|
Termination
|
Screw terminals |
| Cable entry | 3 x M16 x 1,5 |
| Cable section, minimum | 0.25 mm² |
| Cable section, maximum | 2.5 mm² |
| Note (Cable section) | All indications including the conductor ferrules. |
| Mechanical data - Dimensions | |
|
Length of sensor
|
30 mm |
| Width of sensor | 52 mm |
| Height of sensor | 90 mm |
| Ambient conditions | |
|
Degree of protection
|
IP67 |
| Ambient temperature, minimum | -30 °C |
| Ambient temperature, maximum | +80 °C |
| Storage and transport temperature, minimum | -40 °C |
| Storage and transport temperature, maximum | +85 °C |
| Permissible installation altitude above sea level, maximum | 2,000 m |
| Ambient conditions - Insulation values | |
|
Rated insulation voltage Ui
|
500 V |
| Rated impulse withstand voltage Uimp | 6 kV |
| Overvoltage category | III |
| Degree of pollution | 3 |
| Electrical data | |
|
Thermal test current
|
10:00 SA |
| Required rated short-circuit current | 1,000 A |
| Switching element | NO contact, NC contact |
| Switching principle | slow action, positive break NC contact |
| Switching frequency | 4,000 /h |
| Electrical data - Safety contacts | |
|
Voltage, Utilisation category AC-15
|
230 VAC |
| Current, Utilisation category AC-15 | 4:00 SA |
| Voltage, Utilisation category DC-13 | 24 VDC |
| Current, Utilisation category DC-13 | 4:00 SA |
| Electrical data - Auxiliary contacts | |
|
Voltage, Utilisation category AC-15
|
230 VAC |
| Current, Utilisation category AC-15 | 4:00 SA |
| Voltage, Utilisation category DC-13 | 24 VDC |
| Current, Utilisation category DC-13 | 4:00 SA |