Hỗ trợ trực tuyến

Sefety component: RSS16-I2-D-CC Brand: Schmersal

Mã sản phẩm
Sefety component: RSS16-I2-D-CC Brand: Schmersal
Giá
Liên Hệ
Nhà sản xuất
Schmersal
Bảo hành
12 tháng

Ordering data

Product type description

RSS16-I2-D-CC

Article number (order number)

103004351

EAN (European Article Number)

4030661456942

eCl@ss number, Version 9.0

27-27-24-03

eCl@ss number, Version 11.0

27-27-24-03

Approval - Standards

Certificates

TÜV

cULus

EAC

FCC

IC

General data

Standards

IEC 60947-5-3

general information

Individual coding, multiple teaching

Coding level according to ISO 14119

High

Active principle

RFID

Housing construction form

Block

Installation conditions (mechanical)

not flush

Sensor topology

Sensor for series wiring

Enclosure material

Plastic, glass-fibre reinforced thermoplastic, self-extinguishing

Active area

Glass-fibre, reinforced thermoplastic

Gross weight

275 g

Time to readiness, maximum

2,000 ms

Reaction time, maximum

100 ms

Duration of risk, maximum

200 ms

General data - Features

Diagnostic output

Yes

Short circuit detection

Yes

Short-circuit recognition

Yes

Series-wiring

Yes

Safety functions

Yes

Cascadable

Yes

Integral System Diagnostics, status

Yes

Number of LEDs

2

Number of semi-conductor outputs with signaling function

1

Number of fail-safe digital outputs

2

Safety appraisal

Standards

EN ISO 13849-1

IEC 60947-5-3

EN 62061

IEC 61508

Performance level, up to

e

Control category to EN13849

4

PFH-value

6.30 x 10⁻¹¹ /h

Safety Integrity Level (SIL), suitable for applications in

3

Mission Time

20 Year(s)

Mechanical data

Actuating panels

front side

rear

from head

Active area

lateral

front side

cover-side

Hysteresis (Switch distance), maximum

2 mm

Repeat accuracy R R

0.5 mm

Mounting

2 x M5, Cylinder head screw

Tightening torque of nuts, maximum

2 Nm

Mechanical data - Switching distances according IEC 60947-5-3

Switch distance

15 mm

Ensured switch distance "ON" Sao

12 mm

Ensured switch distance "OFF" Sar

30 mm

Mechanical data - Connection technique

Terminal Connector

Spring pulley connection

Note

The cable section of the interconnecting cable must be observed for both wiring variants! Cable length and cable section alter the voltage drop depending on the output current

Mechanical data - Dimensions

Length of sensor

91 mm

Width of sensor

52 mm

Height of sensor

30 mm

Ambient conditions

Degree of protection

IP65 to EN 60529

IP67 to EN 60529

Ambient temperature, minimum

-25 °C

Ambient temperature, maximum

+70 °C

Storage and transport temperature, minimum

-25 °C

Storage and transport temperature, maximum

+85 °C

Restistance to shock

30 g / 11 ms

Protection rating

0

Ambient conditions - Insulation value

Rated insulation voltage Ui

32 VDC

Rated impulse withstand voltage Uimp

0.8 kV

Overvoltage category

III

Degree of pollution to VDE 0100

3

Electrical data

Voltage type

DC (direct current)

No-load supply current I0

100 mA

Rated operating voltage, minimum

20.4 VDC

Rated operating voltage, maximum

26.4 VDC

Operating current

2,100 mA

Required rated short-circuit current to EN 60947-5-1

100 A

Switching frequency, approx.

1 Hz

Electrical data - Fail-safe digital outputs

Rated operating current (safety outputs)

1,000 mA

Output current, (fail-safe output), maximum

1 A

Versions

p-type

Voltage drop Ud, maximum

1 V

Current leakage Ir

0.5 mA

Voltage, Utilisation category DC12

24 VDC

Current, Utilisation category DC12

1 A

Voltage, Utilisation category DC13

24 VDC

Current, Utilisation category DC13

1 A

Electrical data - Diagnostic output

Operating current

50 mA

Versions

p-type

Voltage drop Ud, maximum

2 V

Voltage, Utilisation category DC12

24 VDC

Current, Utilisation category DC12

0.05 A

Voltage, Utilisation category DC13

24 VDC

Current, Utilisation category DC13

0.05 A

Electrical data - Electromagnetic compatibility (EMC)

Ordering data

Product type description

RSS16-I2-D-CC

Article number (order number)

103004351

EAN (European Article Number)

4030661456942

eCl@ss number, Version 9.0

27-27-24-03

eCl@ss number, Version 11.0

27-27-24-03

Approval - Standards

Certificates

TÜV

cULus

EAC

FCC

IC

General data

Standards

IEC 60947-5-3

general information

Individual coding, multiple teaching

Coding level according to ISO 14119

High

Active principle

RFID

Housing construction form

Block

Installation conditions (mechanical)

not flush

Sensor topology

Sensor for series wiring

Enclosure material

Plastic, glass-fibre reinforced thermoplastic, self-extinguishing

Active area

Glass-fibre, reinforced thermoplastic

Gross weight

275 g

Time to readiness, maximum

2,000 ms

Reaction time, maximum

100 ms

Duration of risk, maximum

200 ms

General data - Features

Diagnostic output

Yes

Short circuit detection

Yes

Short-circuit recognition

Yes

Series-wiring

Yes

Safety functions

Yes

Cascadable

Yes

Integral System Diagnostics, status

Yes

Number of LEDs

2

Number of semi-conductor outputs with signaling function

1

Number of fail-safe digital outputs

2

Safety appraisal

Standards

EN ISO 13849-1

IEC 60947-5-3

EN 62061

IEC 61508

Performance level, up to

e

Control category to EN13849

4

PFH-value

6.30 x 10⁻¹¹ /h

Safety Integrity Level (SIL), suitable for applications in

3

Mission Time

20 Year(s)

Mechanical data

Actuating panels

front side

rear

from head

Active area

lateral

front side

cover-side

Hysteresis (Switch distance), maximum

2 mm

Repeat accuracy R R

0.5 mm

Mounting

2 x M5, Cylinder head screw

Tightening torque of nuts, maximum

2 Nm

Mechanical data - Switching distances according IEC 60947-5-3

Switch distance

15 mm

Ensured switch distance "ON" Sao

12 mm

Ensured switch distance "OFF" Sar

30 mm

Mechanical data - Connection technique

Terminal Connector

Spring pulley connection

Note

The cable section of the interconnecting cable must be observed for both wiring variants! Cable length and cable section alter the voltage drop depending on the output current

Mechanical data - Dimensions

Length of sensor

91 mm

Width of sensor

52 mm

Height of sensor

30 mm

Ambient conditions

Degree of protection

IP65 to EN 60529

IP67 to EN 60529

Ambient temperature, minimum

-25 °C

Ambient temperature, maximum

+70 °C

Storage and transport temperature, minimum

-25 °C

Storage and transport temperature, maximum

+85 °C

Restistance to shock

30 g / 11 ms

Protection rating

0

Ambient conditions - Insulation value

Rated insulation voltage Ui

32 VDC

Rated impulse withstand voltage Uimp

0.8 kV

Overvoltage category

III

Degree of pollution to VDE 0100

3

Electrical data

Voltage type

DC (direct current)

No-load supply current I0

100 mA

Rated operating voltage, minimum

20.4 VDC

Rated operating voltage, maximum

26.4 VDC

Operating current

2,100 mA

Required rated short-circuit current to EN 60947-5-1

100 A

Switching frequency, approx.

1 Hz

Electrical data - Fail-safe digital outputs

Rated operating current (safety outputs)

1,000 mA

Output current, (fail-safe output), maximum

1 A

Versions

p-type

Voltage drop Ud, maximum

1 V

Current leakage Ir

0.5 mA

Voltage, Utilisation category DC12

24 VDC

Current, Utilisation category DC12

1 A

Voltage, Utilisation category DC13

24 VDC

Current, Utilisation category DC13

1 A

Electrical data - Diagnostic output

Operating current

50 mA

Versions

p-type

Voltage drop Ud, maximum

2 V

Voltage, Utilisation category DC12

24 VDC

Current, Utilisation category DC12

0.05 A

Voltage, Utilisation category DC13

24 VDC

Current, Utilisation category DC13

0.05 A

Electrical data - Electromagnetic compatibility (EMC)

Interfering radiation

IEC 61000-6-4

EMC rating

IEC 60947-3

Status indication

Note (LED switching conditions display)

Multi-coloured LED: Green, Red

LED yellow: Operating condition

LED green: Supply voltage

LED red: Fault

Scope of delivery

Included in delivery

Actuators must be ordered separately.

Accessory

Recommendation (actuator)

RST16-1

RST-U-2

Recommended safety switchgear

PROTECT PSC1

SRB-E-301ST

SRB-E-201LC

 

Ordering data

Product type description

RSS16-I2-D-CC

Article number (order number)

103004351

EAN (European Article Number)

4030661456942

eCl@ss number, Version 9.0

27-27-24-03

eCl@ss number, Version 11.0

27-27-24-03

Approval - Standards

Certificates

TÜV

cULus

EAC

FCC

IC

General data

Standards

IEC 60947-5-3

general information

Individual coding, multiple teaching

Coding level according to ISO 14119

High

Active principle

RFID

Housing construction form

Block

Installation conditions (mechanical)

not flush

Sensor topology

Sensor for series wiring

Enclosure material

Plastic, glass-fibre reinforced thermoplastic, self-extinguishing

Active area

Glass-fibre, reinforced thermoplastic

Gross weight

275 g

Time to readiness, maximum

2,000 ms

Reaction time, maximum

100 ms

Duration of risk, maximum

200 ms

General data - Features

Diagnostic output

Yes

Short circuit detection

Yes

Short-circuit recognition

Yes

Series-wiring

Yes

Safety functions

Yes

Cascadable

Yes

Integral System Diagnostics, status

Yes

Number of LEDs

2

Number of semi-conductor outputs with signaling function

1

Number of fail-safe digital outputs

2

Safety appraisal

Standards

EN ISO 13849-1

IEC 60947-5-3

EN 62061

IEC 61508

Performance level, up to

e

Control category to EN13849

4

PFH-value

6.30 x 10⁻¹¹ /h

Safety Integrity Level (SIL), suitable for applications in

3

Mission Time

20 Year(s)

Mechanical data

Actuating panels

front side

rear

from head

Active area

lateral

front side

cover-side

Hysteresis (Switch distance), maximum

2 mm

Repeat accuracy R R

0.5 mm

Mounting

2 x M5, Cylinder head screw

Tightening torque of nuts, maximum

2 Nm

Mechanical data - Switching distances according IEC 60947-5-3

Switch distance

15 mm

Ensured switch distance "ON" Sao

12 mm

Ensured switch distance "OFF" Sar

30 mm

Mechanical data - Connection technique

Terminal Connector

Spring pulley connection

Note

The cable section of the interconnecting cable must be observed for both wiring variants! Cable length and cable section alter the voltage drop depending on the output current

Mechanical data - Dimensions

Length of sensor

91 mm

Width of sensor

52 mm

Height of sensor

30 mm

Ambient conditions

Degree of protection

IP65 to EN 60529

IP67 to EN 60529

Ambient temperature, minimum

-25 °C

Ambient temperature, maximum

+70 °C

Storage and transport temperature, minimum

-25 °C

Storage and transport temperature, maximum

+85 °C

Restistance to shock

30 g / 11 ms

Protection rating

0

Ambient conditions - Insulation value

Rated insulation voltage Ui

32 VDC

Rated impulse withstand voltage Uimp

0.8 kV

Overvoltage category

III

Degree of pollution to VDE 0100

3

Electrical data

Voltage type

DC (direct current)

No-load supply current I0

100 mA

Rated operating voltage, minimum

20.4 VDC

Rated operating voltage, maximum

26.4 VDC

Operating current

2,100 mA

Required rated short-circuit current to EN 60947-5-1

100 A

Switching frequency, approx.

1 Hz

Electrical data - Fail-safe digital outputs

Rated operating current (safety outputs)

1,000 mA

Output current, (fail-safe output), maximum

1 A

Versions

p-type

Voltage drop Ud, maximum

1 V

Current leakage Ir

0.5 mA

Voltage, Utilisation category DC12

24 VDC

Current, Utilisation category DC12

1 A

Voltage, Utilisation category DC13

24 VDC

Current, Utilisation category DC13

1 A

Electrical data - Diagnostic output

Operating current

50 mA

Versions

p-type

Voltage drop Ud, maximum

2 V

Voltage, Utilisation category DC12

24 VDC

Current, Utilisation category DC12

0.05 A

Voltage, Utilisation category DC13

24 VDC

Current, Utilisation category DC13

0.05 A

Electrical data - Electromagnetic compatibility (EMC)

-->

Đối Tác

prev
  • Siemens
  • ABB
  • IntensivFilter
  • Schenck
  • đối tác 6
  • Ringspann
  • schaltbau
  • Schmersal
  • Đối tác FPT Smarthome
next