Danh mục sản phẩm
Hỗ trợ trực tuyến
Snap-action switches, S926 series
Công tắc Schaltbau Snap-action switches, S926 series
Specifications
Electrical Data |
|
Contact configuration |
SPDT-DB (Form Zb) snap-action switch with double-break contacts, |
|
10 A at T = 85°C |
|
10 A at T = 85°C |
|
400 V |
|
240 V |
Pollution degree IEC 60947 |
PD 3 |
Pollution degree UL508 |
PD 2 |
|
4 kV |
Utilization category IEC 60947 |
AC-15, 230 VAC/1.0 A / DC-13, 110 VDC/0.5 A |
Utilization category UL508 |
AC 240 V / 1 A general purpose |
|
IP40/IP00 |
Contact material |
Silver or gold |
Short-circuit protection |
6 A gR (silver only) |
Actuators, operating positions |
|
Actuator |
Push button, roller lever |
Free position |
8.85 ±0.20 |
Operating position |
6.60 ±0.35 |
Release position |
7.80 ±0.35 |
Total positive opening travel |
5.85 |
Total travel position |
< 5.65 |
Movement differential (between operating and release position) |
1.2 (typical) |
Mechanical data |
|
Front mount |
yes, front mounting by nut retainers M3 |
Ganging (side mount) |
yes, side mount |
Actuation speed |
max. 1.0 m/s, min. 0.5 mm/s |
Vibration resistance |
10 g (10 … 500 Hz all directions, without aux. actuator at 0.1 ms max. opening time) |
Shock resistance |
30 g, half sinus (without aux. actuator at 0.1 ms max. opening time) |
Housing material |
PEI, amber transparent |
Mechanical endurance |
10 million cycles min. |
Temperature range |
-55 °C ... +105 °C max., dependent on version |
Note |
Data valid for switches with silver contacts. |
Công tắc Schaltbau Snap-action switches, S926 series
Snap-action switches S926 − Variant with ruggedized housing
made from polyetherimide (PEI)
Thanks to the high-performance thermoplastic used as housing material, S926 Series snap-action switches feature both a better resistance to temperature and chemicals as well as a 50% higher impact resistance compared to polycarbonate (PC).
They are ideally suited for applications characterized by harsh environmental conditions. Sharing the same design as the S826 switches, they can easily replace a standard switch without great effort.
Features
- Positive opening operation : Reliable interruption even after contact welding, in compliance with IEC 60947-5-1, Annex K
- Double break contacts: High switching accuracy and resistance to shock and vibration
- Precision switch: High switching accuracy and resistance to shock and vibration
- Wiping contacts : Continuous low contact resistance ensures high contact reliability over the entire design life of the switch
- Magnetic blowout: Optional blowout magnets to extinguish the arc at higher DC loads
- Contact material: Silver or gold
Applications
- Limit switch for use on machines, doors and plant-controls
- Switches for driver‘s cab of rail vehicles and control panels in cranes
- Electromechanical switch for automation tasks
- Safety switch in control units