Danh mục sản phẩm
Hỗ trợ trực tuyến
Sản phẩm đã xem
Switch: EX-ZS 335-11Z-3G/D
Ordering data
| Product type description |
EX-ZS 335-11Z-3G/D |
| Article number (order number) |
101188901 |
| EAN (European Article Number) |
4030661348889 |
| eCl@ss number, Version 9.0 |
27-27-26-01 |
| eCl@ss number, Version 11.0 |
27-27-26-01 |
| ETIM number, version 6.0 |
EC000030 |
| ETIM number, version 7.0 |
EC000030 |
Explosion protection
| Explosion protection: regulations |
BG-GS-ET-15 EN 60079-0 EN 60079-15 EN 60079-31 EN 60947-5-1 |
| Explosion protection zones |
22 2 |
| Explosion protection category |
3D 3G |
| Explosion protection designation |
D II 3G Ex nC IIC T5 Gc X D II 3D Ex tc IIIC T90°C Dc X |
|
Manufacturer declaration |
ATEX Zone 2 and 22 |
General data
| Housing construction form |
Norm construction design |
| Actuator type to DIN EN 50041 |
B |
| Enclosure material |
Aluminium |
| Enclosure coating material |
painted |
| Material of the contacts, electrical |
Silver |
| Gross weight |
225 g |
General data - Features
| Safety functions |
Yes |
| Number of auxiliary contacts |
1 |
| Number of safety contacts |
1 |
Safety appraisal
| Standards |
EN ISO 13849-1 |
| Mission Time |
20 Year(s) |
Safety appraisal - Safety outputs
| B10d Normally-closed contact (NC) |
20,000,000 Operations |
Mechanical data
| Actuating element |
Plunger |
| Mechanical life, minimum |
30,000,000 Operations |
| Impact energy, maximum |
4 J |
| Actuating force, minimum |
12 N |
| Actuating speed, maximum |
0.5 m/s |
| Note Bounce duration |
Bounce duration in accordance with actuating speed |
Mechanical data - Connection technique
| Terminal Connector |
Screw connection |
| Cable cross-section of the cable glands, minimum |
7 mm |
| Cable cross-section of the cable glands, maximum |
12 mm |
| Cable section, minimum |
0.75 mm² |
| Cable section, maximum |
2.5 mm² |
| Note (Cable section) |
All indications about the cable section are including the conductor ferrules. |
| Wire cross-section |
13 AWG |
Mechanical data - Dimensions
| Length of sensor |
38 mm |
| Width of sensor |
40.5 mm |
| Height of sensor |
103.5 mm |
Ambient conditions
| Degree of protection |
IP67 |
| Ambient temperature, minimum |
-20 °C |
| Ambient temperature, maximum |
+60 °C |
Ambient conditions - Insulation value
| Rated insulation voltage Ui |
500 V |
| Rated impulse withstand voltage Uimp |
6 kV |
Electrical data
| Thermal test current |
10 A |
| Utilisation category AC-15 |
230 VAC |
| Utilisation category AC-15 |
4 A |
| Utilisation category DC-13 |
24 VDC |
| Utilisation category DC-13 |
1 A |
| Switching element |
NO contact, NC contact |
| Switching principle |
Snap switch element |
| Switching frequency |
5,000 /h |
| Switchover time, maximum |
2 ms |
Ordering data
| Product type description |
EX-ZS 335-11Z-3G/D |
| Article number (order number) |
101188901 |
| EAN (European Article Number) |
4030661348889 |
| eCl@ss number, Version 9.0 |
27-27-26-01 |
| eCl@ss number, Version 11.0 |
27-27-26-01 |
| ETIM number, version 6.0 |
EC000030 |
| ETIM number, version 7.0 |
EC000030 |
Explosion protection
| Explosion protection: regulations |
BG-GS-ET-15 EN 60079-0 EN 60079-15 EN 60079-31 EN 60947-5-1 |
| Explosion protection zones |
22 2 |
| Explosion protection category |
3D 3G |
| Explosion protection designation |
D II 3G Ex nC IIC T5 Gc X D II 3D Ex tc IIIC T90°C Dc X |
|
Manufacturer declaration |
ATEX Zone 2 and 22 |
General data
| Housing construction form |
Norm construction design |
| Actuator type to DIN EN 50041 |
B |
| Enclosure material |
Aluminium |
| Enclosure coating material |
painted |
| Material of the contacts, electrical |
Silver |
| Gross weight |
225 g |
General data - Features
| Safety functions |
Yes |
| Number of auxiliary contacts |
1 |
| Number of safety contacts |
1 |
Safety appraisal
| Standards |
EN ISO 13849-1 |
| Mission Time |
20 Year(s) |
Safety appraisal - Safety outputs
| B10d Normally-closed contact (NC) |
20,000,000 Operations |
Mechanical data
| Actuating element |
Plunger |
| Mechanical life, minimum |
30,000,000 Operations |
| Impact energy, maximum |
4 J |
| Actuating force, minimum |
12 N |
| Actuating speed, maximum |
0.5 m/s |
| Note Bounce duration |
Bounce duration in accordance with actuating speed |
Mechanical data - Connection technique
| Terminal Connector |
Screw connection |
| Cable cross-section of the cable glands, minimum |
7 mm |
| Cable cross-section of the cable glands, maximum |
12 mm |
| Cable section, minimum |
0.75 mm² |
| Cable section, maximum |
2.5 mm² |
| Note (Cable section) |
All indications about the cable section are including the conductor ferrules. |
| Wire cross-section |
13 AWG |
Mechanical data - Dimensions
| Length of sensor |
38 mm |
| Width of sensor |
40.5 mm |
| Height of sensor |
103.5 mm |
Ambient conditions
| Degree of protection |
IP67 |
| Ambient temperature, minimum |
-20 °C |
| Ambient temperature, maximum |
+60 °C |
Ambient conditions - Insulation value
| Rated insulation voltage Ui |
500 V |
| Rated impulse withstand voltage Uimp |
6 kV |
Electrical data
| Thermal test current |
10 A |
| Utilisation category AC-15 |
230 VAC |
| Utilisation category AC-15 |
4 A |
| Utilisation category DC-13 |
24 VDC |
| Utilisation category DC-13 |
1 A |
| Switching element |
NO contact, NC contact |
| Switching principle |
Snap switch element |
| Switching frequency |
5,000 /h |
| Switchover time, maximum |
2 ms |