General Purpose safety controllers (Series PROTECT SRB)

Code
General Purpose safety controllers (Series PROTECT SRB)
Price
Call
Manufacturer
Schmersal
Warranty
12 months
General Purpose safety controllers (Series PROTECT SRB)
Guard door monitors and Safety control modules for Emergency Stop applications

General Purpose safety controllers (Series PROTECT SRB)

SRB 031LC

• 3 safety contacts, STOP 1
• 1 Signalling output
• Suitable for signal processing of potential-free outputs, e.g. emergency stop command devices, position switches and solenoid interlocks

  Product type description Start-up test (Y/N)    
SRB 031LC-0,6SEC -    

SRB031MC

• Fit for signal evaluation of outputs of safety magnetic switches
• Drop-out delay can be set between 0,4 to 1,5 s
• 3 safety contacts, STOP 1
• 1 Signalling output
• Suitable for signal processing of potential-free outputs, e.g. emergency stop command devices, position switches and solenoid interlocks
• Suitable for signal processing of outputs connected to potentials (AOPDs), e.g. safety light grids/curtains

  Product type description    
SRB031MC-24V/1,1SEC    

SRB200X2

• 2 safety contacts, STOP 0
• Suitable for signal processing of potential-free outputs, e.g. emergency stop command devices, position switches and solenoid interlocks

  Product type description    
SRB200X2    

SRB202C

• Two-functions safety monitoring module (double evaluation)
• 2 enabling paths with different shut-down behaviour, e.g. emergency exit opens both enabling paths (level 1); guard door monitoring only opens the second enabling path (level 2)
• Suitable for signal processing of potential-free contacts, e.g. Emergency Stop command devices (level 1), position switches with safety function, solenoid interlocks and safety sensors (level 2)
• 2 Signalling outputs

  Product type description Reset with edge detection (Y/N) - Short-circuit recognition (Y/N)    
SRB202CA/T 24VDC Yes (Level 1) No (Level 1)  
SRB202CA/Q 24VDC No Yes (Level 1)    
SRB202CA/QT 24VDC Yes (Level 1) Yes (Level 1)    
SRB202CA 24VDC No No (Level 1)    
SRB202CS/T 24VDC Yes (Level 1) No (Level 1)    
SRB202CS 24VDC No No (Level 1)    

SRB206SQ

• 2 safety contacts, STOP 0
• 6 Signalling outputs
• Multi-evaluation of up to 6 safety guards
• Suitable for signal processing of potential-free outputs, e.g. emergency stop command devices, position switches and solenoid interlocks

  Product type description Rated operating voltage Ue Type of actuation    
SRB206SQ-230V 48 ... 240 VAC AC    
SRB 206SQ-24V 24 VDC −15% / +20%, residual ripple max. 10%
24 VAC −15% / +10%
AC/DC    

SRB207AN

• Fit for signal evaluation of outputs of safety magnetic switches
• 2 safety contacts, STOP 0
• 6 Signalling outputs
• Multi-evaluation of up to 6 safety guards
• Suitable for signal processing of potential-free outputs, e.g. emergency stop command devices, position switches and solenoid interlocks

  Product type description Rated operating voltage Ue Type of actuation    
SRB207AN 230VAC 48 … 240 VAC AC    
SRB207AN 24V 24 VDC −15% / +20%, residual ripple max. 10% DC    

SRB 207AN/1

• Suitable for signal processing of potential-free outputs, e.g. emergency stop command devices, position switches and solenoid interlocks
• Fit for signal evaluation of outputs of safety magnetic switches
• 2 safety contacts, STOP 0
• 6 Signalling outputs
Multi-evaluation of up to 6 safety guards

  Product type description    
SRB 207AN/1-230V    

SRB219IT

• Multifunctional safety relay module for superior diagnostics and visualisation
• Fit for signal evaluation of outputs of safety magnetic switches
• 2 safety contacts, STOP 0;
1 safety contact, STOP 1 (adjustable 1 ... 30 s)
• Suitable for signal processing of potential-free outputs, e.g. emergency stop command devices, position switches and solenoid interlocks
• Suitable for signal processing of outputs connected to potentials (AOPDs), e.g. safety light grids/curtains
• 1 + 8 Signalling outputs

  Product type description    
SRB219IT-24VAC/DC    

SRB220XV2 / V.2

• 2 safety contacts, STOP 0; 2 safety contacts, STOP 1

• Suitable for signal processing of potential-free outputs, e.g. emergency stop command devices, position switches and solenoid interlocks
• Suitable for signal processing of outputs connected to potentials (AOPDs), e.g. safety light grids/curtains

  Product type description    
SRB220XV2 / V.2  

SRB 301AN

• Fit for signal evaluation of outputs of safety magnetic switches
• 3 safety contacts, STOP 0
• 1 Signalling output

  Product type description    
SRB301AN 24VAC/DC  

SRB301LC

• 1 Signalling output
• 3 safety contacts, STOP 0
• Suitable for signal processing of potential-free outputs, e.g. emergency stop command devices, position switches and solenoid interlocks

  Product type description Connection type Electronic protection (Y/N)    
SRB301LC 24VAC/DC Screw connection No  
SRB 301LCI/7 Spring pulley connection, plug-in Yes    
SRB 301LCI-24VAC/DC Screw connection Yes    

SRB 301LC/B

• Fit for signal evaluation of outputs of safety magnetic switches (to this end, integrated current and voltage limiters)
• Suitable for signal processing of potential-free outputs, e.g. emergency stop command devices, position switches and solenoid interlocks
• Suitable for signal processing of outputs connected to potentials (AOPDs), e.g. safety light grids/curtains
• 3 safety contacts, STOP 0
• 1 Signalling output

  Product type description    
SRB 301LC/B-24V    

SRB301SQ

• 3 safety contacts, STOP 0
• 1 Signalling output
• Suitable for signal processing of potential-free outputs, e.g. emergency stop command devices, position switches and solenoid interlocks

  Product type description    
SRB301SQ 230V  

SRB 301MC

• Fit for signal evaluation of outputs of safety magnetic switches
• 3 safety contacts, STOP 0
• 1 Signalling output
• Suitable for signal processing of outputs connected to potentials (AOPDs), e.g. safety light grids/curtains
• Suitable for signal processing of potential-free outputs, e.g. emergency stop command devices, position switches and solenoid interlocks

  Product type description    
SRB 301MC-24V  

SRB301ST

• Suitable for signal processing of potential-free outputs, e.g. emergency stop command devices, position switches and solenoid interlocks
• Suitable for signal processing of outputs connected to potentials (AOPDs), e.g. safety light grids/curtains
• Fit for signal evaluation of outputs of safety magnetic switches
• 3 safety contacts, STOP 0
• 1 Signalling output

  Product type description    
SRB301ST-24V-(V.2)    

SRB301ST 230V

• Suitable for signal processing of potential-free outputs, e.g. emergency stop command devices, position switches and solenoid interlocks
• 3 safety contacts, STOP 0
• 1 Signalling output

  Product type description    
SRB301ST 230V  

SRB301X1

• Suitable for signal processing of potential-free outputs, e.g. emergency stop command devices, position switches and solenoid interlocks
• 3 safety contacts, STOP 0
• 1 Signalling output

SRB301X4

• Suitable for signal processing of potential-free outputs, e.g. emergency stop command devices, position switches and solenoid interlocks
• Suitable for signal processing of outputs connected to potentials (AOPDs), e.g. safety light grids/curtains
• 3 safety contacts, STOP 0
• 1 Signalling output

  Product type description Rated operating voltage Ue Type of actuation    
SRB301X4-24V 24 VDC −15% / +20%, residual ripple max. 10%
24 VAC −15% / +10%
AC / DC  
SRB301X4-115V 115 VAC −15% / +10% AC    
SRB301X4-230V 230 VAC −15% / +10% AC    

SRB 302X3

• Suitable for signal processing of potential-free outputs, e.g. emergency stop command devices, position switches and solenoid interlocks
• Suitable for signal processing of outputs connected to potentials (AOPDs), e.g. safety light grids/curtains
• 3 safety contacts, STOP 0
• 2 Signalling outputs

  Product type description Rated operating voltage Ue Type of actuation    
SRB 302X3-24V-230V 230 VAC −15% / +10%
24 VDC −15% / +20%, residual ripple max. 10%
24 VAC −15% / +10%
AC    
SRB 302X3-24V-115V 115 VAC −15% / +10%;
24 VDC −15% / +20%, residual ripple max. 10%
24 VAC −15% / +10%
AC / DC    

SRB304ST

• Suitable for signal processing of potential-free outputs, e.g. emergency stop command devices, position switches and solenoid interlocks
• Suitable for signal processing of outputs connected to potentials (AOPDs), e.g. safety light grids/curtains
• Fit for signal evaluation of outputs of safety magnetic switches
• 3 safety contacts, STOP 0
• 4 Signalling outputs

  Product type description    
SRB304ST    

SRB308IT

• Multifunctional safety relay module for superior diagnostics and visualisation
• Suitable for signal processing of potential-free outputs, e.g. emergency stop command devices, position switches and solenoid interlocks
• Suitable for signal processing of outputs connected to potentials (AOPDs), e.g. safety light grids/curtains
• Fit for signal evaluation of outputs of safety magnetic switches
• 3 safety contacts, STOP 0
• 2 + 6 Signalling outputs

  Product type description    
SRB308IT-230VAC    
SRB308IT-24VAC/DC    
SRB 308IT-115V    

SRB320XV3 / V.2

• Suitable for signal processing of potential-free outputs, e.g. emergency stop command devices, position switches and solenoid interlocks
• Suitable for signal processing of outputs connected to potentials (AOPDs), e.g. safety light grids/curtains
• 3 safety contacts, STOP 0; 2, safety contacts STOP 1

SRB324ST

• Suitable for signal processing of potential-free outputs, e.g. emergency stop command devices, position switches and solenoid interlocks
• Suitable for signal processing of outputs connected to potentials (AOPDs), e.g. safety light grids/curtains
• 3 safety contacts, STOP 0;
2 safety contacts, STOP 1 (adjustable 1 ... 30 s)
• 4 Signalling outputs

  Product type description    
SRB324ST 24V (V.3)  

SRB400C.

• Two-functions safety monitoring module (double evaluation)
• 2 x 2 enabling paths with different shut-down behaviour, e.g. emergency exit opens both enabling paths (level 1); guard door monitoring only opens the second enabling path (level 2)
• Suitable for signal processing of potential-free contacts, e.g. Emergency Stop command devices (level 1), position switches with safety function, solenoid interlocks and safety sensors (level 2)

  Product type description Reset with edge detection (Y/N) - Short-circuit recognition (Y/N)    
SRB 400CA/T-24V Yes (Level 1) No (Level 1)  
SRB400CS 24VDC No No (Level 1)  
SRB400CA/Q 24VDC No Yes    
SRB400CA/QT 24VDC Yes Yes    
SRB400CA 24VDC No No    
SRB400CS/T 24VDC Yes (Level 1) No (Level 1)    

SRB504ST

• Suitable for signal processing of potential-free outputs, e.g. emergency stop command devices, position switches and solenoid interlocks
• Suitable for signal processing of outputs connected to potentials (AOPDs), e.g. safety light grids/curtains
• Fit for signal evaluation of outputs of safety magnetic switches
• 5 safety contacts, STOP 0
• 4 Signalling outputs

  Product type description    
SRB504ST  

RB301HC/R

• 3 safety contacts, STOP 0
• 1 Signalling output
• Suitable for signal processing of potential-free outputs, e.g. emergency stop command devices, position switches and solenoid interlocks and Two-hand control panels and Safety mats

  Product type description Rated operating voltage Ue Type of actuation    
SRB301HC/R-24V 24 VDC −15% / +20%, residual ripple max. 10%
24 VAC −15% / +10%
AC / DC  
SRB301HC/R-230V 48 ... 240 VAC AC  

SRB301HC/T

• 3 safety contacts, STOP 0
• 1 Signalling output
• Suitable for signal processing of potential-free outputs, e.g. emergency stop command devices, position switches and solenoid interlocks and Safety mats

  Product type description Rated operating voltage Ue Type of actuation    
SRB301HC/T-24V 24 VDC −15% / +20%, residual ripple max. 10%
24 VAC −15% / +10%
AC / DC  
SRB301HC/T-230V 48 ... 240 VAC AC    

SRB400NE

• Fit for signal evaluation of outputs of safety magnetic switches (to this end, integrated current and voltage limiters)
• Possibility to connect a non-contact end switch or speed reduction switch
• 2 safety contacts, switch-off level 1;
2 safety contacts, switch-off level 2

  Product type description Rated operating voltage Ue Type of actuation    
SRB400NE 24V 24 VDC −15% / +20%, residual ripple max. 10%
24 VAC −15% / +10%
AC/DC  
SRB400NE 230V 230 VAC −15% / +10% AC    

SRB402NE

• Fit for signal evaluation of outputs of safety magnetic switches (to this end, integrated current and voltage limiters)
• Possibility to connect a non-contact end switch or speed reduction switch
• 2 safety contacts, switch-off level 1;
2 safety contacts, switch-off level 2
• 2 Signalling outputs

  Product type description Rated operating voltage Ue Type of actuation    
SRB402NE 230V 230 VAC −15% / +10% AC    
SRB402NE 24V 24 VDC −15% / +20%, residual ripple max. 10%
24 VAC −15% / +10%
AC/DC    

SRB301MA

• 1 Signalling output
• Suitable for signal processing of potential-free outputs, e.g. emergency stop command devices, position switches and solenoid interlocks
• Fit for signal evaluation of outputs of safety magnetic switches
• 3 safety contacts, STOP 0
• Suitable for signal processing of outputs connected to potentials (AOPDs), e.g. safety light grids/curtains

  Product type description    
SRB301MA-24V  

SRB201LC

• Suitable for signal processing of potential-free outputs, e.g. emergency stop command devices, position switches and solenoid interlocks
• 2 safety contacts, STOP 0
• 1 Signalling output

  Product type description Rated operating voltage Ue Type of actuation    
SRB201LC 24 VDC −15% / +20%, residual ripple max. 10%
24 VAC −15% / +10%
AC/DC    

SRB211LT

• Suitable for signal processing of potential-free outputs, e.g. emergency stop command devices, position switches and solenoid interlocks
• 1 Signalling output
• 2 safety contacts, STOP 0
• 1 safety contact, STOP 1
• Multi-evaluation of up to 6 safety guards
• Fit for signal evaluation of outputs of safety magnetic switches

  Product type description    
SRB211LT/CC    
SRB211LT/PC    

SRB 301LC/8

• Suitable for signal processing of potential-free outputs, e.g. emergency stop command devices, position switches and solenoid interlocks
• 3 safety contacts, STOP 0, 1 Auxiliary contact

  Product type description    
SRB 301LC/8    

SRB 324LT

• Suitable for signal processing of potential-free outputs, e.g. emergency stop command devices, position switches and solenoid interlocks
• Suitable for signal processing of outputs connected to potentials (AOPDs), e.g. safety light grids/curtains
• 3 safety contacts, STOP 0;
2 safety contacts, STOP 1 (adjustable 1 … 30 s)
• 3 Signalling outputs, 1 Auxiliary contact

  Product type description    
SRB 324LT-480S    

 

 

 

General Purpose safety controllers (Series PROTECT SRB)

SRB 031LC

• 3 safety contacts, STOP 1
• 1 Signalling output
• Suitable for signal processing of potential-free outputs, e.g. emergency stop command devices, position switches and solenoid interlocks

  Product type description Start-up test (Y/N)    
SRB 031LC-0,6SEC -    

SRB031MC

• Fit for signal evaluation of outputs of safety magnetic switches
• Drop-out delay can be set between 0,4 to 1,5 s
• 3 safety contacts, STOP 1
• 1 Signalling output
• Suitable for signal processing of potential-free outputs, e.g. emergency stop command devices, position switches and solenoid interlocks
• Suitable for signal processing of outputs connected to potentials (AOPDs), e.g. safety light grids/curtains

  Product type description    
SRB031MC-24V/1,1SEC    

SRB200X2

• 2 safety contacts, STOP 0
• Suitable for signal processing of potential-free outputs, e.g. emergency stop command devices, position switches and solenoid interlocks

  Product type description    
SRB200X2    

SRB202C

• Two-functions safety monitoring module (double evaluation)
• 2 enabling paths with different shut-down behaviour, e.g. emergency exit opens both enabling paths (level 1); guard door monitoring only opens the second enabling path (level 2)
• Suitable for signal processing of potential-free contacts, e.g. Emergency Stop command devices (level 1), position switches with safety function, solenoid interlocks and safety sensors (level 2)
• 2 Signalling outputs

  Product type description Reset with edge detection (Y/N) - Short-circuit recognition (Y/N)    
SRB202CA/T 24VDC Yes (Level 1) No (Level 1)  
SRB202CA/Q 24VDC No Yes (Level 1)    
SRB202CA/QT 24VDC Yes (Level 1) Yes (Level 1)  
-->

Partners